BSBWM - POLY(1-BUTENE) ISOTACTIC, 337
- MSDS: BSBWM
- Manufacturer: SCIENTIFIC POLYMER PRODUCTS INC
- Product Name: POLY(1-BUTENE) ISOTACTIC, 337
- National Stock Number: 9330-00N044051
Product Identification
Product ID:POLY(1-BUTENE) ISOTACTIC, 337
MSDS Date:03/01/1992
FSC:9330
NIIN:00N044051
MSDS Number: BSBWM
Responsible Party
ONTARIO, NY 14519
US
Emergency Phone: 716-265-0413
Info Phone: 716-265-0413
Cage: 0MUG0
Contractor
Telephone: 716-265-0413
Cage: 0MUG0
Ingredients
POLYBUTYLENE
CAS: 9003-28-5
Fraction By Weight: >99.9%
OSHA PEL N/K
ACGIH TLV: N/K
MINOR ADDITIVES
Fraction By Weight: <0.1%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MATERIAL IS CONSIDERED A SLIGHT EYE
IRRITANT; MAY ALSO BE IRRITATING TO SENSITIVE SKIN. NO OTHER HEALTH
EFFECTS ARE KNOWN TO EXIST.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:IN ALL CASES, IF IRRITATION DEVELOPS, SEEK MEDICAL
ASSISTANCE. INHAL: REMOVE FROM EXPOSURE. IF BREATHING STOPS, BEGIN
MOUTH TO MOUTH. EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. SKIN:
WASH AFFECTED AR EA WITH SOAP AND WATER. REMOVE DIRTY CLOTHING.
INGEST: GET MD IMMEDIATELY .
Fire Fighting
Extinguishing Media:CO2, FOAM, DRY CHEMICALS, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL PROT
EQUIP . DO NOT USE DIRECT WATER STREAM; AVOID ACCUMULATION OF WATER
AS PROD WILL FLOAT. TREAT AS (SUPP DATA)
Unusual Fire/Explosion Hazard:NONE KNOWN.
Accidental Release
Spill Release Procedures:ELIMINATE ALL OPEN FLAMES. SWEEP UP AND PLACE
IN CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM SOURCES THAT CAN BURN.
TRACE QUANTITIES OF VOLATILE HYDROCARBONS MAY BE PRESENT IN STORAGE
CNTNRS.
Other Precautions:ALL EQUIP MUST BE GROUNDED TO PVNT ACCUM OR STATIC
CHARGE. ALLOW CNTNRS TO VENT AFTER OPENING & BEFORE HNDLG. STORE
AWAY FROM OXIDIZING MATLS IN A COOL, DRY PLACE W/ADEQ VENT. KEEP
CNTNRS TIGHTLY SEAL ED.
Exposure Controls
Respiratory Protection:IF NEEDED. NIOSH/MSHA APPROVED RESPIRATOR
APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPR CHEMICAL SAFETY GOGGLES
Work Hygienic Practices:GOOD HYGIENE PRACTICES SHOULD BE STRICTLY
FOLLOWED.
Supplemental Safety and Health
% VOLAT: 0.20 (WT). FIRE FIGHT PROC: SOLID THAT CAN BURN; KEEP AWAY
FROM IGNITION SOURCES.
Chemical Properties
HCC:N1
Melt/Freeze Pt:M.P/F.P Text:>255F,>124C
Spec Gravity:0.915
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID PELLET; SLIGHT ODOR.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:CONTACT WITH STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:CARBON MONOXIDE, ORGANICS OF UNKNOWN
CHEMICAL COMPOSITION AND TOXICITY.
Disposal
Waste Disposal Methods:LANDFILL OR INCINERATE IN ACCORDING TO STATE,
FEDERAL, AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.